Seite 1 - PC-IP SOFTWARE

User ManualPC-IP SOFTWAREFor the CM100 IP, CM250 IP, and CM500 IP

Seite 2

Chapter 1 Software Overview 3 For proper operation, the Belkin adapter and software should be installed before your PC-IP software. If necessary, un-

Seite 3 - Install Profiler

Chapter 9 Reference 93 Anonymous FTP Access Anonymous access is not required by the CM500 IP and in general should be avoided. Although your site is

Seite 4 - Contents

PC-IP Software User’s Manual 94 to upload files to your server’s default uploads directory. Select Delete Permission to allow users to delete or overw

Seite 5

Chapter 9 Reference 95 Use the Max Total Connections setting to limit the number of simultaneous connections to your server. Setting this to an appro

Seite 6

PC-IP Software User’s Manual 96 Auto Start On The auto start feature allows the FTP server to start automatically when the program is launched. This c

Seite 7

Chapter 9 Reference 97 FTP Server Cache Settings Figure 9-5 Cache Files Meteor FTP can be configured to maintain caches of the most frequently access

Seite 8 - General Information

PC-IP Software User’s Manual 98 CACHE DIRECTORY REQUESTS Similarly, to cache directory requests, check the “Cache Directory Listings” check box and se

Seite 9 - PC REQUIREMENTS

Chapter 9 Reference 99 Figure 9-6 RUNNING THE METEOR FTP SERVER Basic FTP server operations ACTIVATEUSER ACCOUNTSSERVER STATUSREFRESH DIRECTORY CACHE

Seite 10 - PREPARATION FOR USE

PC-IP Software User’s Manual 100 Users Button This button displays the User Administration dialog to setup and manage user accounts. Font Button This

Seite 11 - WARRANTY

Chapter 9 Reference 101 Figure 9-7 Click on the Add button to add a new user. The Add User dialog is displayed. Figure 9-8 Enter the user logon name

Seite 12 - Chapter 1

PC-IP Software User’s Manual 102 Users must have READ, WRITE and DELETE privileges on the FTP server. Read allows the users to download files for down

Seite 13

PC-IP Software User’s Manual 4 Registration The PC-IP software is a licensed software package intended for installation on one PC and should not be co

Seite 14 - Getting Started

Chapter 9 Reference 103 example, to block all computers with IP addresses starting with “207”, enter “207.*.*.*” in the edit box and click enter. Not

Seite 15

PC-IP Software User’s Manual 104 Ban: Adds the user’s IP address to the list of blocked IP addresses if IP filtering is set to the block mode. Discon

Seite 16 - Chapter 2

Chapter 9 Reference 105 Cache View Dialog The cache view dialog allows you to view the files and directories currently stored in the server cache and

Seite 17

PC-IP Software User’s Manual 106 Figure 9-14 Use the R, G and B sliders to select the desired color combination. Command Line Options Meteor FTP suppo

Seite 18

Chapter 9 Reference 107 APPENDIX B: CHANNEL TABLES The channel table is used by the Install Profiler to define the channel names, frequencies, type o

Seite 19

PC-IP Software User’s Manual 108 US, Germany, China and UK Default Channel Plans U.S.A. U.S.A. U.S.A. GERMANY CHINA UKHRC IRC Standard PAL B/G PAL D P

Seite 20 - Using the PC-IP Software

Chapter 9 Reference 109 U.S.A. U.S.A. U.S.A. GERMANY CHINA UKHRC IRC Standard PAL B/G PAL D PAL I HRC35 288.0144 35 289.2625 36 295.2625 S29 367.25 Z

Seite 21

PC-IP Software User’s Manual 110 U.S.A. U.S.A. U.S.A. GERMANY CHINA UKHRC IRC Standard PAL B/G PAL D PAL I HRC78 546.0273 78 547.2625 79 553.25 51 711

Seite 22 - SOFTWARE OVERVIEW

Chapter 9 Reference 111 U.S.A. U.S.A. U.S.A. GERMANY CHINA UKHRC IRC Standard PAL B/G PAL D PAL I HRC126 804.0402 126 805.2625 127 811.25127 810.0405

Seite 23

PC-IP Software User’s Manual 112 Additional Channel Plans: Japan, South Korea, Taiwan, Spain and Poland JAPAN S. KOREAHONG KONGTAIWAN SPAIN POLANDNTSC

Seite 24 - Chapter 3

Chapter 1 Software Overview 5 No other warranty is expressed or implied. Sunrise is not liable for consequential damages. From time to time, Sunrise

Seite 25

Chapter 9 Reference 113 JAPAN S. KOREAHONG KONGTAIWAN SPAIN POLANDNTSC M NTSC M PAL I NTSC PAL B/G PAL B/GC40 325.25 36 295.25 60 783.25 36 295.2625

Seite 26

PC-IP Software User’s Manual 114 JAPAN S. KOREAHONG KONGTAIWAN SPAIN POLANDNTSC M NTSC M PAL I NTSC PAL B/G PAL B/G32 585.25 79 553.25 51 711.25 K58 7

Seite 27

Chapter 9 Reference 115 JAPAN S. KOREAHONG KONGTAIWAN SPAIN POLANDNTSC M NTSC M PAL I NTSC PAL B/G PAL B/G127 811.25128 817.25129 823.25130 829.25131

Seite 28

PC-IP Software User’s Manual 116 License Agreement PC-IP Software License Agreement WARNING: SUNRISE TELECOM, INC. IS WILLING TO LICENSE THE ENCLOSED

Seite 29

Chapter 9 Reference 117 RESTRICTIONS. You may not: • permit other individuals to use the Software except under the terms listed above; • permit con

Seite 30 - PC-IP Operation

PC-IP Software User’s Manual 118 or its suppliers be liable for any special, incidental, indirect, or consequential damages whatsoever (including with

Seite 31

Chapter 9 Reference 119 TO THE TERMS SET FORTH HEREIN, AND NOT THOSE IN YOUR PURCHASE ORDER. If any provision of this Agreement is held to be unenfor

Seite 32 - Chapter 4

PC-IP Software User’s Manual 120

Seite 33

PC-IP Software User’s Manual 6

Seite 34

Chapter 2 Getting Started 7 Chapter 2 Getting Started WHAT YOU WILL NEED To complete the installation and operation of the PC-IP software, you shoul

Seite 35 - CHANNEL TABLE SETUP

PC-IP Software User’s Manual 8 3. When the window for the CD-ROM files opens, click on the setup program, PC-IP setup.exe, and click Enter. A Welcome

Seite 36

Chapter 2 Getting Started 9 5. The initial process is to check the PC for existing copies of PC-IP and to begin extracting files, the screen (Figure

Seite 37

PC-IP Software User’s Manual 10 7. On the Choose Destination Location screen, accept the proposed file directory or enter a new one and click Next. F

Seite 38

Chapter 2 Getting Started 11 9. When the Select Components screen is displayed, select Next to continue the installation. All components are require

Seite 39

PC-IP Software User’s Manual 12 11. Following the file transfer shown, display will provide a Windows message that “Install Shield Wizard Complete”.

Seite 40

Contents i PC-IP Software for the CM100 IP, CM250 IP, CM500 IP User’s Manual Version 1.00 November 2003 Part number: MAN-22417-US001

Seite 41

Chapter 3 Using PC-IP Software 13 Chapter 3 Using the PC-IP Software Opening the Install Profiler Software Following installation, the PC-IP Software

Seite 42

PC-IP Software User’s Manual 14 When the software key is obtained, type or copy it into the box labeled “Software Key” and click on the Key button. Un

Seite 43

Chapter 3 Using PC-IP Software 15 SOFTWARE OVERVIEW The PC-IP software allows to direct interfacing with the Install Profiler via the RS-232 connecti

Seite 44

PC-IP Software User’s Manual 16 Limits Setup Selects the measurements that will be made in the SMART auto tests and sets the pass/fail measurement lim

Seite 45 - CABLE MODEM SETUP

Chapter 3 Using PC-IP Software 17 RealView Allows the user to set up the connection to the realWORX controller, IP Address and Port number. The confi

Seite 46

PC-IP Software User’s Manual 18 Connecting to the Install Profiler When the PC-IP Software is opened, it automatically opens a data link with the Inst

Seite 47

Chapter 3 Using PC-IP Software 19 Figure 3-4 When the connection issue is resolved, the PC-IP software will re-connect. Load The Load icon opens a wi

Seite 48

PC-IP Software User’s Manual 20 Figure 3-5 Viewing Files Select a file from the list labeled CM500 Files, as shown in Figure 3-5, and click on Load. T

Seite 49

Chapter 3 Using PC-IP Software 21 View Cable Modem Range & Register details of a saved SMART test file. View Upstream Spectrum or RealView measur

Seite 50 - LIMITS SETUP

PC-IP Software User’s Manual 22 Clearing or Deleting Files Clicking on any of the files in the list and then the Delete File button deletes those sele

Seite 51

Install Profiler User’s Manual ii DISCLAIMER Information in this document is subject to change without notice and does not represent a commitment on t

Seite 52

Chapter 4 PC-IP Operation 23 Chapter 4 PC-IP Operation GENERAL SETUP The general setup screen provides basic configuration information, including dat

Seite 53

PC-IP Software User’s Manual 24 Time & Date - The time and date displayed on this screen are from your PC’s internal clock. If they are not correc

Seite 54

Chapter 4 PC-IP Operation 25 Serial Port - The default serial port is displayed. To change the serial port setting, click on the box to select the a

Seite 55 - UPSTREAM SPECTRUM

PC-IP Software User’s Manual 26 System Info System Info provides information on the Install Profiler currently connected to the PC. To view the inform

Seite 56

Chapter 4 PC-IP Operation 27 Current Database This displays the current database in use with the full path and file name. The user may click on the d

Seite 57

PC-IP Software User’s Manual 28 CHANNEL TABLE SETUP The Channel Table Selection screen is shown in the Figure 4-2. Clicking on the Channel Table Icon

Seite 58

Chapter 4 PC-IP Operation 29 Procedure for Getting a Channel Table To download the current channel table(s) from the Install Profiler, select the des

Seite 59 - PILOT GENERATOR (OPTION)

PC-IP Software User’s Manual 30 Modulation - The type of modulation expected may be setup by selecting from NTSC, 64 QAM, 256 QAM, PAL-B, PAL-B/G, PAL

Seite 60

Chapter 4 PC-IP Operation 31 Figure 4-3 Digital Pilots - Digital pilots are set to the lowest and highest digital channel. These channels are used to

Seite 61

PC-IP Software User’s Manual 32 Figure 4-5 Editing the Channel Table Select the channel table to be edited by clicking on the Channel Table tab at the

Seite 62

Contents iii Contents Chapter 1 General Information ... 1 Install Profiler Configuration ...

Seite 63 - CLONE UTILITY

Chapter 4 PC-IP Operation 33 Figure 4-6 Enter the new Channel ID – one to four alphanumeric digits. Figure 4-7 Select the frequency from the pull dow

Seite 64

PC-IP Software User’s Manual 34 Figure 4-10 Select the Modulation type from the pull down menu. Figure 4-11 Select the symbol rate from the pull down

Seite 65

Chapter 4 PC-IP Operation 35 Select the appropriate video to audio frequency offset for the second audio carrier of the channel (0.0 to 8.0 MHz). Set

Seite 66 - Viewing Files

PC-IP Software User’s Manual 36 Figure 4-16 Multiple channels may be edited in a single column by highlighting the cells and double right clicking on

Seite 67

Chapter 4 PC-IP Operation 37 Figure 4-17 Note: If a connection to your Install Profiler is not established, it may take several seconds before a mess

Seite 68 - ANALOG CHANNELS

PC-IP Software User’s Manual 38 Print Select the Print icon from the main tool bar to print the current Channel Table configuration screen in a databa

Seite 69

Chapter 4 PC-IP Operation 39 Getting Cable Modem Data The current configuration of the Install may also be viewed by clicking on the Get button. You

Seite 70 - Chapter 5

PC-IP Software User’s Manual 40 administrator prior to registering on the network must provision this address. If User Defined is selected, the user w

Seite 71 - VIEW SCAN SAVED FILE

Chapter 4 PC-IP Operation 41 second level as the User ID and the third level the file name. See the Appendix A for information on setting up your FTP

Seite 72

PC-IP Software User’s Manual 42 Configuration The configuration setup allows you to download configuration files to set up your CM500 IP over the netw

Seite 73

Install Profiler User’s Manual iv To Get All Channel Tables ... 29 Channel Table Information ...

Seite 74

Chapter 4 PC-IP Operation 43 User Name - Most FTP servers require a login user name. Enter the user name for the FTP server here. The default user na

Seite 75

PC-IP Software User’s Manual 44 for a comprehensive set of test results. PC-IP software facilitates ensuring that all your Install Profilers are ident

Seite 76

Chapter 4 PC-IP Operation 45 Figure 4-22 Limits are also used in the manual screens to provide Pass/Fail indicators on the graphic displays and to pr

Seite 77

PC-IP Software User’s Manual 46 Location Figure 4-23 Three test locations are provided, each with their own set of limits. Select a Location Tab befor

Seite 78

Chapter 4 PC-IP Operation 47 Analog Tests: Video Carrier Level, Video to Audio Ratio, Adjacent Channel, Tilt, Peak to Valley and Video to Audio 2 Rat

Seite 79

PC-IP Software User’s Manual 48 when the program is opened. You may use the database or download the data from an Install Profiler that has already be

Seite 80

Chapter 4 PC-IP Operation 49 PC-IP software. The typical setup is to measure a TDMA upstream signal on marker M1, to measure interference or distorti

Seite 81

PC-IP Software User’s Manual 50 at M2 and is displayed next to the M2 marker. Calculations are then made to calculate C/I that is the difference in le

Seite 82

Chapter 4 PC-IP Operation 51 Figure 4-26 Frequency - Double click on the Frequency box to enter the desired frequency for each marker. Any frequency

Seite 83

PC-IP Software User’s Manual 52 Send Upstream Setup to the Install Profiler After editing the Upstream Setup, you may upload or send the information t

Seite 84

Contents v Chapter 5 Viewing Files ... 59 View Signal Level Meter Saved File ...

Seite 85

Chapter 4 PC-IP Operation 53 Figure 4-27 Print Select the Print icon from the main menu to print the current configuration screen in a database forma

Seite 86

PC-IP Software User’s Manual 54 and measuring leakage in confined areas, such as hallways of apartment buildings, steam tunnels, and crowded city stre

Seite 87 - IMPORTING RESULTS DATA

Chapter 4 PC-IP Operation 55 Leakage Limit - Select Set Llimit and use the arrow keys to increment the display to the desired limit to trigger the le

Seite 88

PC-IP Software User’s Manual 56 CLONE UTILITY The Clone feature is effectively copies all of the configuration information from one Install Profiler t

Seite 89

Chapter 4 PC-IP Operation 57 Getting Information from the Install Profiler To download database configuration Setup information (Figure 4-29) from an

Seite 90 - Upgrade Procedures

PC-IP Software User’s Manual 58

Seite 91

Chapter 5 Viewing Files 59 Chapter 5 Viewing Files Figure 5-1 Select a file from the list labeled Install Profiler Files (Figure 5- 1). Select the de

Seite 92 - Sunrise Service and Support

PC-IP Software User’s Manual 60 0.5 dBmV, NTSC modulation, a video to audio carrier level ratio of –10.4 dB and an adjacent channel ratio of +1.0 dB.

Seite 93

Chapter 5 Viewing Files 61 The V/A Ratio is only calculated and displayed for the primary audio carrier, although both are compared to the criteria f

Seite 94 - Specifications

PC-IP Software User’s Manual 62 result of the difference in level between the video carrier level measurement and the measurement of the upper adjacen

Seite 95

Install Profiler User’s Manual vi Logon Accounts File ... 92 Record Log ...

Seite 96 - Reference

Chapter 5 Viewing Files 63 Analysis Display – The channel number and modulation type are displayed the same as analog channels. Similarly, the locati

Seite 97

PC-IP Software User’s Manual 64 VIEW SCAN SAVED FILE When the Scan icon is in color, it means that the current file is a Scan saved file and can be vi

Seite 98

Chapter 5 Viewing Files 65 Figure 5-4 Figure 5-4 shows the typical recalled Scan display. Markers provide the channel indication and level for the ch

Seite 99

PC-IP Software User’s Manual 66 Zoom Box – Clicking on the Zoom Box button allows the user to place a box over the area of the bar graph, which he wis

Seite 100 - Chapter 9

Chapter 5 Viewing Files 67 Location – The location indicates the current set of Limits criteria used for the Pass/Fail analysis: Set-Top, Ground Blo

Seite 101 - PC-IP Software

PC-IP Software User’s Manual 68 to Valley), Maximum Adjacent Channel Deviation plus Digital Tilt, Digital P/V (Peak to Valley), and the A/D (Analog to

Seite 102

Chapter 5 Viewing Files 69 appear in a pop up window and include the Channel Number, Video Carrier (or Digital) Level, Audio Carrier Level, Delta (vi

Seite 103

PC-IP Software User’s Manual 70 Figure 5-8 shows an Excel spreadsheet created by pasting the copied Detail Data into the top left cell of the spreadsh

Seite 104

Chapter 5 Viewing Files 71 Figure 5-9 Analog Screen Figure 5-10 Digital Screen

Seite 105

PC-IP Software User’s Manual 72 View Cable Modem Range & Register Details of a Saved SMART Test File. When the Cable Modem icon is in color, it me

Seite 106

Chapter 1 Software Overview 1 Chapter 1 General Information PC-IP is a licensed software product included with the CM100 IP, CM250 IP, and CM500 IP I

Seite 107

Chapter 5 Viewing Files 73 Downstream The results of the Downstream DOCSIS channel measurements are displayed providing information about the perform

Seite 108

PC-IP Software User’s Manual 74 properly configured in the Cable Modem Setup screen to provide accurate results. See Appendix A for details on setting

Seite 109

Chapter 5 Viewing Files 75 Ranging TFTP - Pass / Fail – Indicating whether the internal cable modem was able to download the TFTP file from the TFTP

Seite 110

PC-IP Software User’s Manual 76 Figure 5-12 shows the typical recalled Upstream Spectrum display. Markers provide the frequency indication and level w

Seite 111

Chapter 5 Viewing Files 77 File Next to the bar graph are a series of measurement information displays in tabular and text form. Technician - The nam

Seite 112

PC-IP Software User’s Manual 78 Ingress Figure 5-13 Figure 5-13 shows the typical recalled ingress display. Markers provide the frequency indication a

Seite 113

Chapter 5 Viewing Files 79 maximum level displayed on the vertical axis and the lower box is the minimum level displayed on the vertical axis. The us

Seite 114 - APPENDIX B: CHANNEL TABLES

PC-IP Software User’s Manual 80 Details Noise Margin - Displays the difference between the measured noise level and the programmed Limit. This is not

Seite 115

Chapter 5 Viewing Files 81 Figure 5-14

Seite 116

PC-IP Software User’s Manual 82

Seite 117

PC-IP Software User’s Manual 2 • Leakage Option – Leakage channel, limit, unit of measure, distance and tag settings. • RealView – realWORX controll

Seite 118

Chapter 6 Upgrade Procedures 83 Chapter 6 Upgrade Procedures PC-IP SOFTWARE Downloading Replacement Software The latest upgrades are always available

Seite 119 - HONG KONG

PC-IP Software User’s Manual 84 previous database from the CM500 IP where you uploaded your database prior to the upgrade. Installing the CM500 IP Upg

Seite 120

Chapter 7 Service and Support 85 Chapter 7 Sunrise Service and Support Sunrise is committed to excellent service worldwide. Our goal is to provide yo

Seite 121

PC-IP Software User’s Manual 86

Seite 122

Chapter 8 Specifications 87 Chapter 8 Specifications PC Requirements 300 MHz Pentium PC or better Windows™ 98, ME, NT, XP or 2000 32M RAM CD-ROM Dri

Seite 123 - License Agreement

PC-IP Software User’s Manual 88

Seite 124

Chapter 9 Reference 89 Chapter 9 Reference APPENDIX A: EXAMPLE FTP SETUP Introduction Meteor FTP software is a shareware program which can be used to

Seite 125

PC-IP Software User’s Manual 90 IP address of the server, a user name, password and a file name for the download will need to be programmed into the C

Seite 126

Chapter 9 Reference 91 CONFIGURE SERVER PATHS Figure 9-1 This dialog is used to set the default directories and file locations used by the server. FT

Seite 127

PC-IP Software User’s Manual 92 Default Uploads Directory This is the default directory where user uploaded files are stored. The upload location can